Troubleshooting 
Trouble Probable 
Cause 
Remedy 
Motor will not run. 
No incoming power, or low voltage. 
Check hoist connections to power 
source. If low voltage, have certified 
electrician check incoming power. 
Fuse blown or circuit breaker tripped. 
Replace fuse/re-set circuit breaker.  
Rectifier damaged in the phase 
protector so that the brake won’t work. 
Replace phase protector.  
Transformer damaged. 
Replace transformer. 
Motor damaged. 
Have motor replaced by a qualified 
service technician. 
Hoist lifts but will not 
lower. 
Broken conductor in pendant cord. 
Test continuity of each conductor. 
Replace cable if needed. 
Up/down switch malfunctioning. 
Repair or replace switch. 
Hoist lowers but will 
not lift. 
Overloaded. 
Reduce load to within hoist capacity. 
Up/down switch malfunctioning. 
Repair or replace switch. 
Clutch malfunction. 
Have clutch replaced by qualified 
personnel. 
Load continues drifting 
down excessively 
when hoist is stopped. 
Grease or oil on the lining. 
Open the hoist, disassemble the brake 
and clean the lining. 
Disc brake is worn. 
Adjust clearance between armature and 
iron core. See page 16. 
Brake springs are damaged. 
Replace brake springs. 
Hoist moves in wrong 
direction. 
Two of the three power supply wires are 
switched. 
Switch any two of the three supply wires 
(see page 10). 
Motor overheats. 
Excessive load or too frequent use. 
Operate within rated load and according 
to duty cycle rating. 
Brake drags. 
Adjust brake clearance (see page 16). 
Poor engagement of 
chain with 
sprocket/sheave. 
Load chain seriously worn. 
Replace load chain. See pages 14 and 
15 . 
Sprocket wheel, sheave or the chain 
guide is seriously worn. 
Replace parts as needed. 
Will not lift rated load. 
Overload limit clutch friction torque too 
low. 
Readjust the overload clutch to proper 
limits (qualified personnel only). 
Overload limit clutch damaged. 
Replace overload limit clutch. 
Limit switch failure. 
Bad connection of limit switch leads. 
Inspect the contacts of the leads and 
limit switches. 
Limit switch damaged. 
Replace limit switch.