WOS-127 & 130 SINGLE WALL OVENS
The WOS-127 and WOS-130 single ovens may be installed below the DCS CT-365 gas cooktop in a
standard 36” tall (to counter surface) base cabinet. Refer to diagram shown below for cabinet and
countertop cutout dimensions.
The gas shut-off valve and power supply receptacle for the cooktop must remain accessible from the
front after the units are installed. It is suggested that the valve and receptacle be located in the
cabinet adjacent to the wall oven on the right. To prevent interference with the wall oven chassis, the
cooktop gas regulator must be mounted at the shut-off valve. Use approved flexible gas tubing to
make the connection between the regulator and the cooktop.
Install the cooktop into the countertop first. Make the connections to the gas and power supplies as
per the cooktop installation instructions. Verify that the electrical service to the oven is shut off. Make
the power supply connections for the wall oven and then slide the unit into the cabinet. Secure unit
to cabinet as noted in  “Mounting the Wall Oven” section. Turn on all utilities and check both units for
proper operation.
WARNING:
When pushing wall oven into cabinet, be careful not to pinch the gas
connection to the cooktop.
Min.
Cabinet Face
19-3/4"
 
34-3/4"
 
1-1/2"
 
4-3/4"
 
25-1/2"
 
28-5/16"
 
+ 1/16"
 
- 0"
 
(27" Oven)
28-1/2"
 
(30" Oven)
36" 
24" 
UNDER COUNTER INSTALLATION WITH CT-365