IQinVision IQA15 Installation Instruction

Page of 12
6
7.  Removal of Dome Cover and Camera 
Assembly
1.  Using the supplied Torx T-20 security tool,  
loosen the four screws holding the dome cover  
to the rest of the Alliance camera assembly.   
Note that these screws are captively held to the  
dome cover and should not be removed from  
the dome cover trim ring.
2.  Once loosened, lift the dome cover and trim  
ring away from the camera assembly.
3.  Locate the removal tabs where the camera  
assembly connects to the mounting plate as  
shown in 
Figure 7.1
.
4.  Press any two of the three removal tabs and pivot the camera assembly up and 
away from the mounting plate. Carefully thread the connection cables out 
through the mounting plate hole. 
8. Install Mounting Plate
1.  Position the supplied mounting template on the surface in the location where the 
camera will be installed. Trace and drill the mounting holes and the cable pass 
through hole as indicated.
2.  Using the supplied hardware, or equivalent hardware, install the mounting plate 
to the intended surface. 
3. Pull cabling through the pass-through hole.
     
NOTE: If you are installing your Alliance into a ceiling tile, please be sure to 
use hardware designed to secure the camera assembly to such a surface, and 
that the ceiling tile material being mounted is secure. 
Figure 7.1
Removal Tabs