6.1 
RS-232 Connection 
and Port Configuration
To interface the DHD Controller with a home theater automation/control system or a PC 
running terminal emulation software, connect it to your control system or PC as shown in 
Figure 3-16. Use a null-modem cable. 
If you are using a PC to communicate with the DHD Controller: 
1. Start a terminal session on your PC using a terminal-emulation program, such as 
HyperTerminal. 
2. Configure the PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow 
control. Set the baud rate to 19200, to match that of the DHD Controller RS-232 port.
3. Press <Enter>. You should see a command prompt (>) in the terminal window. 
4. Type a command from among those listed in Table 6-1 and press <Enter>.
 
6.2 
Serial Command 
Syntax
• Commands are in ASCII format and are not case-sensitive; on and ON are equivalent. 
• For a command that takes no parameters, type the command followed by a carriage 
return; for example, to turn on the system, type ON<Enter>
• For a command that takes a parameter, type the command, one or more spaces and 
the desired value followed by a carriage return; for example, to switch to the S-Video 
input, type SSRC 1<Enter>
• When you enter a valid command, the DHD Controller executes it. When you send an 
on/off, input selection, aspect ratio or image preset command, the DHD Controller also 
responds with an acknowledgment on the command line. For example, when you issue 
the command SAR 2, the DHD Controller responds with Letterbox on the 
command line. 
• When you enter a misspelled or otherwise invalid command, the DHD Controller 
ignores it and responds with Invalid Command on the command line. 
• When you send a command followed by values outside the valid range for that 
command, the DHD Controller ignores it and responds with Invalid Parameter 
on the command line.
• When the DHD Controller receives an OFF command, it will not acknowledge or 
execute any commands for approximately 90 seconds afterwards. This is to prevent 
hot re-strikes of the lamp, which can damage it.