Cleveland oeb-6.10 User Manual

Page of 8
Cleveland
Project  ________________________________
Item  __________________________________
Quantity  _______________________________  
FCSI Section  ____________________________
Approval  _______________________________
Date  __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110 
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com  
 
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.20 on OGB 10.20 or OGS 6.20 on OGS 10.20)
SECT.
IIB
PAGE 
5D
0707
by
by
Cleveland
Cleveland
Model #
Description
CSTK-1020
for mounting one 6.20 model on top of one 10.20 model
CSTK-1020CA
for mounting one 6.20 model on top of one 10.20 model (with casters)
UNIT A
UNIT B
0
6.20
on 10.20
GAS
6
8
0
.0
9
"
47.92"
2.52"
1.58"
1.82"
3
0
.1
2
"
5.00
"
3
8
.9
8
"
6.00"
8
1
.0
0
(M
IN
.H
O
O
D
R
E
Q
U
IR
E
M
E
N
T
)
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
48.32"
47.72"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
N
6.10
on 10.10
GAS
R
RC
CS
W1
W2
D
G
48.54”
39.21"
N
UNIT A
UNIT B
LEFT SIDE VIEW
U
7
8
.4
1
"
36.70"
1.58"
1.82"
2
8
.4
3
5.00"
3
8
.9
8
"
8
0
.0
0
(M
IN
.H
O
O
D
R
E
Q
U
IR
E
M
E
N
T
)
2.52"
7
UTILITIES
(Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
• Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
120 volt, 60 Hz, single phase, UNIT A - 11.7 amps
Do not connect to a G.F.I. outlet.
UNIT B - 15.9 amps
Gas Connection:
3/4" NPT
Gas Type:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
BOILER MODELS
UNIT A - OGB-6.20
UNIT B - OGB-10.20
Total Connected Load:
75,700 BTU
132,700 BTU
Steam Generator:
68,200 BTU
113,600 BTU
Hot Air:
75,700 BTU
132,700 BTU
BOILERLESS MODELS
UNIT A - OGS-6.20
UNIT B - OGS-10.20
Total Connected Load:
75,700 BTU
132,700 BTU
Steam Generator:
75,700 BTU
132,700 BTU
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, see spec sheet for each
individual combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
W1
W2
D
RC
S
CS
AV
G
E1
E2