Hitachi Travelstar 7K500 160GB HTS725016A9A361 User Manual

Product codes
HTS725016A9A361
Page of 176
7K500 OEM Specification 
Page 139 of 176 
 
14.37
14.37
14.37
14.37  Set Max A
Set Max A
Set Max A
Set Max Address
ddress
ddress
ddress E
 E
 E
 Ext 
xt 
xt 
xt (37h) 
(37h) 
(37h) 
(37h)      
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data Low 
-     Data Low 
Data High 
-     Data High 
Current 
-     Error 
...See Below... 
Feature 
Previous 
-       
  
Current 
-  B    
HOB=0  - 
Sector Count 
Previous 
-    
Sector Count 
HOB=1  - 
Current 
V  V  V  V  V  V  V  V    
HOB=0  V  V  V  V  V  V  V  V 
LBA Low 
Previous 
V  V  V  V  V  V  V  V    
LBA Low 
HOB=1  V  V  V  V  V  V  V  V 
Current 
V  V  V  V  V  V  V  V    
HOB=0  V  V  V  V  V  V  V  V 
LBA Mid 
Previous 
V  V  V  V  V  V  V  V    
LBA Mid 
HOB=1  V  V  V  V  V  V  V  V 
Current 
V  V  V  V  V  V  V  V    
HOB=0  V  V  V  V  V  V  V  V 
LBA High 
Previous 
V  V  V  V  V  V  V  V    
LBA High 
HOB=1  V  V  V  V  V  V  V  V 
Device 
-  1  - 
-     Device 
Command 
0  0  1  1  0  1  1  1     Status 
...See Below... 
 
Error Register 
  
Status Register 
  
CRC  UNC 
IDN 
ABT  T0N  AMN     BSY  RDY  DF  DSC  DRQ  COR  IDX  ERR 
  
Table 107 Set Max Address Ext Command (37h)   
This command is immediately preceded by a Read Native Max Address Ext command.   
This  command  overwrites  the  maximum  number  of  Address  of  HDD  in  a  range  of  actual  device 
capacity.  Once  device  receives  this  command,  all  accesses  beyond  that  Address  are  rejected  with 
setting ABORT bit in status register.   
When the address requested is greater than 268,435,455, words (103:100) shall be modified to reflect 
the requested value, but words (61:60) shall not modified. When the address requested is equal to or 
less  than  268,435,455,  words  (103:100)  shall  be  modified  to  reflect  the  requested  value,  and  words 
(61:60) shall also be modified.   
If this command is not supported, the maximum value to be set exceeds the capacity of the device, a 
host  protected  area  has  been  established  by  a  Set  Max  Address  command,  the  command  is  not 
immediately preceded by a Read Native Max Address Ext command, or the device is in the Set Max 
Locked or Set Max Frozen state, the device shall return command aborted.   
The  device  returns  the  command  aborted  for  a  second  non-volatile  Set  Max  Address  Ext  command 
until next power on.   
Output Parameters To The Device 
B 
Option bit for selection whether nonvolatile or volatile. B=0 is volatile 
condition. When B=1, Max Address which is set by Set Max Address 
Ext command is preserved by POR. When B=0, Max Address which is 
set by Set Max Address Ext command will be lost by POR. 
LBA Low Current 
Set Max LBA (7:0). 
LBA Low Previous 
Set Max LBA (31:24). 
LBA Mid Current 
Set Max LBA (15:8). 
LBA Mid Previous 
Set Max LBA (39:32). 
LBA High Current 
Set Max LBA (23:16). 
LBA High Previous 
Set Max LBA (47:40). 
Input Parameters From The Device 
LBA Low (HOB=0) 
Set Max LBA (7:0).