Hussmann fmss-l Data Sheet

Page of 5
 
1 of 5 
FMSS-L 
Technical Data Sheet 
 
 
Rev A
Specialty Products 
FMSS-L 
       
 
 
REFRIGERATION DATA 
Note: This data is based on store temperature and 
humidity that does not exceed 75F and 55% R.H.
 
 
 
 
 
 
Discharge Air (F) 
-5 
 
 
Evaporator (F) 
20 
 
Note: Not recommended to control temp by regulating 
coil temp allow t-stat to cycle and control temp. 
 
 
 
 
Btu/hr/ft 
Parallel   
    800 
   
Conventional             920  
 
 
 
*For all refrigeration equipment other than Hussmann, 
use conventional Btu values. 
 
DEFROST DATA 
Frequency Hrs  
 
 
OFFTIME  
Temp Term °F 
54 
Failsafe Minutes  
26 
          
 
ELECTRIC or GAS     Not Recommended 
 
 
 
PHYSICAL DATA 
Merchandiser Drip Pipe (in.) 
1 ½* 
Merchandiser Liquid Line (in.) 
3/8* 
Merchandiser Suction Line (in.) 
5/8* 
 
Estimated Charge (lb)*** 
4ft 1.2 
5ft 1.5 
6ft 1.8 
 
*Dependent on case length and refrigerant type. 
 
*** This is an average for all refrigerants types.  Actual 
refrigerant charge may vary by approximately half a 
pound. 
GLYCOL REQUIREMENTS 
   
 
 
 
  GPM           PSI 
 
 
 NA 
 
NA   
 
 
  NA         
NA 
 
 
 
  NA         
NA 
 
 
Engineering 
CROSS SECTION  
 
 
 
 
 
These merchandisers are manufactured to meet ANSI/National Sanitation 
Foundation Standard #7 requirements.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 CUL Listed 
 
 
 
  
     UL Sanitation 
We reserve the right to change or revise specifications and 
product design in connection with any feature of our 
products.  Such changes do not entitle the buyer to 
corresponding changes, improvements, additions or 
replacements for equipment previously sold or shipped.