Immunity Characteristics 
•  EN55024:1998+A1:2001 
•  IEC 61000-4-2:2001 Electrostatic Discharge Immunity Test 
•  IEC 61000-4-3:2002 Radiated Radio-Frequency Electromagnetic Field Immunity Test 
•  IEC 61000-4-4:1995+A1:2000+A2: 2001 Electrical Fast Transient/Burst Immunity Test 
•  IEC 61000-4-5:2001 Surge Immunity Test 
•  IEC 61000-4-6:2001 Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields 
•  IEC 61000-4-8:2001 Power Frequency Magnetic Field Immunity Test 
•  IEC 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests 
Safety 
•  UL/CSA 60950-1 
Environmental Specifications 
Temperature  
•  Operating: 
-10 to 55 °C 
•  Operating  
Survival: 
-25 to 65 °C 
•  Storage: 
-30 to 75 °C 
Humidity  
•  Operating: 
5 to 90% RH, 40 °C, non-condensing  
•  Non-operating: 
5 to 93% RH, non-condensing  
Altitude 
•  Operating: 
10,000 ft (IEC 60068 PT2-13, 4 hours) 
•  Non-operating: 
15,000 ft (IEC 60068 PT2-13, 4 hours) 
Vibration 
•  Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis 
Shock  