Planar LX1200 User Guide

Page of 29
LX1200TI User’s Guide (020-0512-01A)              
25
Environmental Specifi cations
    Temperature
 
   • Operating: -20° to 60° C
    • Operating Survival: -25° to 65° C
    • Storage: -20° to +70° C
    Humidity
 
   • Operating: 5 to 90% RH, 40° C, non-condensing
    • Non-operating: 5 to 93% RH, non-condensing
    Altitude
 
   • Operating: 10,000 ft (IEC 60068 PT2-13, 4 hours)
    • Non-operating: 15,000 ft (IEC 60068 PT2-13, 4 hours)
    Vibration
 
   • Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis 
    Shock
 
   • Operating/Non-operating: 50 G, 11 ms duration, 1/2 sine, 3 shocks per 
        axis (IEC 60068 PT2-27)
Connectors
 
• J1: Video Input
      •  15-pin D-Sub VGA, female, Zhangjiagang SBFR15 or equivalent
  •  J2: Power Interrupt
      •  CviLux CP35 2P*H00 (black); terminal part number 43030-0007
      •  Mating connector is Molex Micro Fit Jr., Molex part number 43025-0200, 
        terminal part number 43030-0007.
      •  The power interrupt switch is connected to a single pole single throw 
        normally open push button (SPST N.O) switch. This can be connected to your 
        docking station or computer’s power button.
  •  J3: Audio Input
    • 3mm 
jack
  •  J4: USB Upstream Type B
      •  Type B for connecting to the computer