Planar lc640.480.21-065 Product Manual
LC640.480.21-065 Operations Manual (OM610-00)
4
Specifications
Performance characteristics are guaranteed with the display at room temperature (25 °C)
and with the operating voltage within specifications, unless otherwise specified. Optical
performance is referenced to screen center at normal incidence with a full white screen
display and the backlight at maximum luminance, 60Hz LCD frame rate, unless
otherwise specified.
and with the operating voltage within specifications, unless otherwise specified. Optical
performance is referenced to screen center at normal incidence with a full white screen
display and the backlight at maximum luminance, 60Hz LCD frame rate, unless
otherwise specified.
Environmental Characteristics
Table 2. Environmental Characteristics.
Temperature
Operating
Operating survival
Storage
-20 to +71 °C (-40 to +71°C with cell heater/version -01)
-40 to +85 °C, 2 hrs. maximum
-45 to +90 °C, 24 hrs. maximum
Humidity
Operating
Non-operating
Non-operating
93% RH @ 40 °C, non-condensing, 10 days per IEC 68-2-3
0 to 95% RH @ 25-55 ºC, 6 days per IEC 68-2-30
0 to 95% RH @ 25-55 ºC, 6 days per IEC 68-2-30
Altitude
Operating
Non-operating
Non-operating
0 to 10k ft. per IEC 68-2-13
0 to 40k ft. per IEC 68-2-13
0 to 40k ft. per IEC 68-2-13
Vibration (random)
Operating/Non-operating
0.02 g
2
/Hz, 5-500 Hz, 30 min. ea. axis, per IEC 68-2-34
Specific profiles for each axis, SAE J1455, section 4.9
Shock
Operating/Non-operating
100 g, 6 ms, half sine wave, 3 shocks per surface, per IEC 68-2-27
Safety and EMI Certifications
The display will not inhibit the end product from compliance with UL1950, CSA22.2,
and IEC950. When housed in a suitable enclosure, the display will not inhibit the end
product from complying with FCC Part 15, Subpart J Class B, EN55022 Class B, or
SAE-J-1113.
and IEC950. When housed in a suitable enclosure, the display will not inhibit the end
product from complying with FCC Part 15, Subpart J Class B, EN55022 Class B, or
SAE-J-1113.
Reliability and Backlight Life
The demonstrated system MTBF is to be greater than 30,000 hours with a 90%
confidence level at 25 °C. Refer to Table 3 for backlight life.
confidence level at 25 °C. Refer to Table 3 for backlight life.
Table 3. Backlight Life.
Usage
Backlight life (typical to 50% of initial luminance)
Continuous at full luminance
20K hours
Continuous at half luminance
60K hours
Typical use using CBM*
50K hours @ 700 cd/m
2