In Simulation mode you can select the looped or cross-looped B channels and 
display the connected remote number in the last line of the screen of page 2, if 
available. If the delay is available for the selected channel, § 3.13.3, the instrument 
displays it in alternation with the connected number. Press ENTER on the selected 
channel to disconnect the associated call.  
In Monitor mode you can select the B channels with activity and display the 
connected remote number in the last line of the display, if available. Press ENTER on 
the selected channel to listen to the audio of the associated call. 
 
In Monitor mode information on the B channel is only given with 
the 'MONITOR' test in progress and only refers to the 
connections established after the START. 
Depending on the device owned, you will have the following displays:  
 
Selects a B channel and displays the remote number 
connected. 
 
 
PRI simulation 
 
 
BRI simulation 