Aethra d2000 lite User Manual

Page of 186
MANUALE D’USO 
                                          ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000 
 
In this configuration, information such as FRAME and CRC SYNC, LFA alarms, AIS 
and RAI, LOCAL CRC and REMOTE CRC errors is not available over the frame. 
7.3.2. G.826 
 
Page 4 shows the values detected according to G.826 to monitor the in-service line 
quality parameters. 
 
Goes to page 4. 
 
This measure is disabled if an Unframed G.703 at 2Mbit test is 
carried out. 
This standard, valid for 2Mb connections or higher, allows to check the access quality 
without performing specific off-service tests, such as BERT G.821. See § 0. 
G.826 measures errors and alarms in the flow through the analysis of the 
synchronism blocks (LFACRC4) intrinsically contained in the frame. 
The results allow to measure the unavailability flow time (UAS), number of errored 
seconds (ES), number of severely errored seconds (SES) and errored blocks 
(BBER) both in uni-directional mode for each direction (Downstream, Upstream) and 
in bi-directional mode, by considering the flow as a single communication channel. 
Values are shown both in absolute (ABS) and ration (RATIO) format. The  
PASS/FAIL test refers to the quality objectives set in G.826. 
CAPITOLO 7. SMART STATUS 
123