Aethra avc8500 User Guide

Page of 88
 
SAFETY RULES 
 
DEVICE IN CLASS I 
Always connect to a grounded socket. 
 
CAUTION: double pole / neutral fusing. 
 
CAUTION: for continued protection against risk of fire, replace 
only with same type and rating of fuses. 
 
Connect the ISDN port to a network termination only (NT1). It is 
absolutely forbidden to connect the system to an outdoor 
telecommunication line. 
 
Connect the LAN port to an internal LAN circuit only. It is 
absolutely forbidden to connect the system to an outdoor 
telecommunication line. 
 
PAN & TILT connector: this output provide a Limited Power 
Sources DC output. 
 
This equipment will be inoperable when mains power fail. 
 
The change from cold to hot environments can cause the 
formation of condensate inside the device. To avoid 
malfunctioning, wait at least 2 hours before connecting the device 
to the supply mains. 
 
In case of fire, absolutely avoid using water to extinguish it. 
 
WARNING: RISK OF ELECTRIC SHOCK 
The power supply used by this device involves lethal voltage 
levels. 
 
Do not access internal parts of the device (and/or of the power 
supply unit). 
 
If objects or liquids penetrate inside the device, immediately 
disconnect the power supply cable. Before using the device 
again, have it checked by specialized staff. 
 
Refer to qualified staff for service. 
 
In case of intervention, always check that the power supply has 
been completely and successfully disconnected. 
ENVIRONMENTAL WARD 
CAUTION: risk of explosion if batteries are replaced by an 
incorrect type. Dispose of used batteries according to the 
instructions. 
The batteries of this equipment must be recycled by a company 
in charge of this activity, a company qualified for the disposal of 
dangerous materials or by using containers provided for the 
separate collection of worn out batteries. 
This equipment may not be treated as household waste. Instead it 
shall be handed over to the applicable collection point for the 
recycling of electrical and electronic equipment. By ensuring this 
product is disposed of correctly, you will help prevent potential 
negative consequences for the environment and human health, 
which could otherwise be caused by inappropriate waste handling 
of this product. For more detailed information about recycling of 
this product, please contact your local city office, your household 
waste disposal or the dealer where you purchased this product. 
CLEANING 
To clean the device use a soft cloth either dry or moistened with a 
little detergent. Never use any type of solvents, such as alcohol or 
gasoline, to avoid damaging the finish. 
 
REGIONAL REQUIREMENTS 
Laitte on liitettävä suojamaadoituskoskettimilla varustettuun 
pistorasiaan. 
Apparatet må tilkoples jordet stikkontakt. 
Apparaten skall anslutas till jordat uttag. 
INSTALLATION WARNING FOR RACK MOUNT USAGE 
Tmra – The manufacturer’s maximum recommended ambient 
temperature is 40 °C. 
Elevated Operating Ambient Temperature – If installed an a 
closed or multi-unit rack assembly, the operating ambient 
temperature of the rack environment may be grater than room 
ambient. Therefore consideration should be given to installing 
the equipment in an environment compatible with the 
manufacturer’s maximum rated ambient temperature (Tmra). 
Reduce Air Flow – Installation of equipment in a rack should be 
such that the amount of air flow required for safe operation of 
the equipment is not compromised. 
Mechanical Loading – Mounting of the equipment in the rack 
should be such that a hazardous condition is not achieved due 
to uneven mechanical loading. 
Circuit Overloading – Consideration should be given to the 
connection of the equipment to the supply circuit and the effect 
that overloading of circuits might have on overcurrent protection 
and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this 
concern. 
Reliable earthing – Reliable earthing of rack-mounted equipment 
should be maintained. Particular attention should be given to 
supply connection other than direct connection to the branch 
circuit (e.g., use of power strips). 
WARNINGS 
CAUTION: many of the components used in this device are 
sensitive to electrostatic charge. 
In case of manipulation of the connection cables, disconnect the 
power supply and avoid direct contacts with the connector 
terminals. 
When handling electronic components, to eliminate any static 
electricity touch a grounded surface. If possible, wear a 
grounding arm band. 
Failure to comply with these warnings could cause permanent 
damage to device. 
EN 55022 Class A COMPLIANCE 
This is a Class A product. In a domestic environment this product 
may cause radio interference in which case the user may 
required to take adequate measures. 
FCC 15 Class A COMPLIANCE 
This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.