Valcom v2991 Installation Instruction

Page of 3
 
 
Issue 1 
 
 
1 
947611 
   
 
 
 
 
V-2991 
CALL SWITCH WITH VOLUME CONTROL 
 
 
INTRODUCTION 
The V-2991, Call Switch with Volume Control, is 
designed to be used with Valcom Talkback Page 
Control Units with the remote calling feature.  
The V-2991 provides a call button for connection 
to customer provided signaling equipment. 
 
FEATURES 
•  Modern décor styling 
•  Designed to fit in a standard single-gang 
electrical box 
•  No external power source required 
•  Black "Call" button for call annunciation 
•  Built-in Volume Control 
 
DIMENSIONS/WEIGHT 
•  4.50"H x 2.75"W x 1.00"D 
(11.43cm H x 6.99cm W x 2.54cm D) 
•  0.2 lbs. (.09 kg) 
  
INSTALLATION 
These instructions cover only the installation 
procedures for the Valcom V-2991.  Consult the 
installation instructions of other equipment for 
information relative to each piece of equipment. 
 
1.  Connect switch inputs from control unit to  
V-2991 as shown in connection diagram. 
2.  Connect audio Tip and Ring from control 
unit to V-2991 as shown in connection 
diagram. 
3.  Connect V-2991 to audio Tip and Ring of 45 
Ohm Talkback Speaker. 
4.  Press call button to test loudness of tone at 
speaker and adjust volume of tone through  
cut-out on the front of the V-2991 enclosure 
using a 1/16 inch flat tip screwdriver. 
5.  Place V-2991 over standard single-gang 
electrical box and fasten in place using the 
two screws provided.