Viewsonic PJ400 User Manual

Page of 61
ViewSonic PJ400 
51 
Phenomena that may easily be mistaken for machine defects (continued) 
Phenomenon 
Cases not involving a machine defect 
Reference Page 
 
The lens cover is closed. 
Remove the lens cover. 
4, 16 
The signal cables are not correctly connected.
Correctly connect the connection cables. 
13, 14 
The brightness is adjusted to an extremely 
low level. 
Adjust the BRIGHT to a higher level using the 
menu function or the remote control. 
25, 27 
No pictures are 
displayed. 
The computer cannot detect the projector as 
a plug and play monitor. 
Make sure that the computer’s can detect a plug 
and play monitor using other plug and play 
monitor. 
13 
Color settings are not correctly adjusted. 
Perform picture adjustments by changing the 
COLOR TEMP, COLOR, TINT and/or COLOR 
SPACE settings, using the menu functions. 
25, 28, 32 
Colors have a 
faded-out 
appearance,  
or 
Color tone is 
poor. 
COLOR SPACE setting is not suitable. 
Change the COLOR SPACE setting to AUTO, 
RGB, SMPTE240, REC709 or REC601.   
32 
The brightness and/or contrast are adjusted 
to an extremely low level

Adjust the BRIGHT and/or CONTRAST 
settings to a higher level using the menu 
function. 
25, 27 
The WHISPER function is working. 
Select the NORMAL to the item WHISPER in 
the SETUP menu. 
26, 34 
Pictures appear 
dark. 
The lamp is approaching the end of its 
product lifetime. 
Replace the lamp. 
41, 42, 44 
Either the focus and/or horizontal phase 
settings are not properly. 
Adjust the focus using the focus ring, and/or H 
PHASE using the menu function. 
19, 30 
Pictures appear 
blurry. 
The lens is dirty or misty. 
Clean the lens by referring to the section 
“Caring for the lens”. 
45 
 
NOTE  • Although bright spots or dark spots may appear on the screen, this is a 
unique characteristic of liquid crystal displays, and such do not constitute or imply a 
machine defect.