Viking Range dgcu105 Installation Guide
3
DESCRIPTION
DGCU105 (30” W.)
DGCU165 (36” W.)
DGCU155 (45” w.)
Cutout Width - Minimum
28 3/4” (73.0 cm)
34 1/2” (87.6 cm)
42 7/8” (108.9 cm)
Maximum
29 7/8” (75.9 cm)
35 7/8” (91.1 cm)
44 1/8” (112.1 cm)
Cutout Height - Minimum
2 3/4” (7.0 cm)
Cutout Depth - Minimum
19 11/16” (50.0 cm)
Maximum
20 1/2” (52.1cm)
Overall Width
30 3/4” (78.1 cm)
36 3/4” (93.3 cm)
45” (114.3 cm)
Overall Height from Bottom
(including connector)
(including connector)
4 1/4” (10.8 cm)
Overall Depth from Rear
21” (53.3 cm)
Gas Requirements
Not field convertible - Must be ordered from factory either natural or LP/Propane.
Uses
standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements
120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.
Maximum Amp Usage
2.0 amps
Surface Burner Rating
Left Front-
14,000 Nat./13,500 LP (BTU)
12,000 Nat./11,500 LP (BTU)
12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
(3.5 Nat./2.8 LP [kw])
(3.5 Nat./2.8 LP [kw])
Left Rear-
12,000 Nat./11,500 LP (BTU)
10,000 Nat./LP (BTU)
8,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw])
(2.9 Nat./LP [kw])
(2.1 Nat./LP [kw])
Left Center
N/A
14,000 Nat./13,500 LP (BTU)
10,000 Nat./LP (BTU)
(4.1 Nat./4.0 LP [kw])
(2.9 Nat./LP [kw])
Right Center
N/A
N/A
14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear-
8,000 Nat./LP (BTU)
8,000 Nat./LP (BTU)
6,000 Nat./LP (BTU)
(2.1 Nat./LP [kw])
(2.1 Nat./LP [kw])
(1.8 Nat./LP [kw])
Right Front-
6,000 Nat./LP (BTU)
6,000 Nat./LP (BTU)
8,000 Nat./LP (BTU)
(1.8 Nat./LP [kw])
(1.8 Nat./LP [kw])
(2.1 Nat./LP [kw])
Approximate Shipping Weight
67 lb. (30.2 kg.)
80 lb. (36.0 kg)
93 lb. (41.9 kg)
DESCRIPTION
VGSU103 (30” W.)
VGSU163 (36” W.)
Cutout Width - Minimum
26 7/8” (68.3 cm)
34 3/8” (87.3 cm)
Maximum
29 7/8” (75.9 cm)
35 7/8” (91.1 cm)
Cutout Height - Minimum
2 1/2” (6.4 cm)
Cutout Depth - Minimum
18 5/8” (47.3 cm)
Maximum
20 1/8” (51.1cm)
Overall Width
30 3/4” (78.1 cm)
36 3/4” (93.3 cm)
Overall Height from Bottom
5” (12.7 cm)
Overall Depth from Rear
21” (53.3 cm)
Gas Requirements
To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.
Uses standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements
120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.
Maximum Amp Usage
2.0 amps
Surface Burner Rating
Left Front-
16,000 Nat./15,500 LP (BTU)
16,000 Nat./15,500 LP (BTU)
(4.8 Nat./4.65 LP [kw])
(4.8 Nat./4.65 LP [kw])
Left Rear-
12,000 Nat./11,500 LP (BTU)
12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw])
(3.6 Nat./3.45 LP [kw])
Center Front/Rear
N/A
12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw])
Right Rear-
8,000 Nat./7,500 LP (BTU)
8,000 Nat./7,500 LP (BTU)
(2.4 Nat./2.25 LP [kw])
(2.4 Nat./2.25 LP [kw])
Right Front-
6,000 Nat./5,500 LP (BTU)
6,000 Nat./5,500 LP (BTU)
(1.8 Nat./1.65 LP [kw])
(1.8 Nat./1.65 LP [kw])
Approximate Shipping Weight
67 lb. (30.2 kg.)
80 lb. (36.0 kg)