Hitachi ed-pj32 User Manual

Page of 59
54
Troubleshooting
Regarding the indicator lamps
Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP 
indicator have the meanings as described in the table below. Please follow the 
instructions within the table. If the same indication is displayed after the remedy, 
or if an indication other than the following is displayed, please contact your dealer 
or service company.
POWER 
indicator
LAMP 
indicator
TEMP 
indicator
Description
Lighting 
In 
Orange
Turned 
off
Turned 
off
The projector is in a standby state.
Please refer to the section “Power On/Off”.(19)
Blinking 
In 
Green
Turned 
off
Turned 
off
The projector is warming up.
Please wait.
Lighting 
In 
Green
Turned 
off
Turned 
off
The projector is in an on state.
Ordinary operations may be performed.
Blinking 
In 
Orange
Turned 
off
Turned 
off
The projector is cooling down.
Please wait.
Blinking 
In 
Red
(discre-
tionary)
(discre-
tionary)
The projector is cooling down. A certain error 
has been detected.
Please wait until the POWER indicator finishes 
blinking, and then perform the proper measure, 
referring to the item descriptions below.
Blinking 
In 
Red
 
or 
Lighting 
In 
Red
Lighting 
In 
Red
Turned 
off
The lamp does not light, and there is a 
possibility that interior portion has become 
heated.
Please turn the power off, and allow the projector to 
cool down at least 20 minutes. After the projector has 
sufficiently cooled down, please make confirmation of 
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy, 
please change the lamp referring to the section “Lamp”
(48, 49).
Blinking 
In 
Red
 
or 
Lighting 
In 
Red
Blinking 
In 
Red
Turned 
off
The lamp cover has not been properly fixed. 
Please turn the power off, and allow the projector to 
cool down at least 45 minutes. After the projector has 
sufficiently cooled down, please make confirmation 
of the attachment state of the lamp cover. After 
performing any needed maintenance, turn the power 
on again. If the same indication is displayed after 
the remedy, please contact your dealer or service 
company.