Delfield ffsc-2 Specification Guide

Page of 2
PROJECT
ITEM #
QUANTITY   
 
DATE
APPROVAL
The Delfield Company, 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. ©2002 The Delfield Company. All rights reserved. Printed in U.S.A. 
Built-in self-contained ice cream dispensers
Short form specifications
The exterior sides and top edge shall be 20-gauge galvanized steel. 
Exterior bottom to be 14-gauge galvanized steel.
Inner liner shall be water-tight and constructed of 22-gauge stainless 
steel with a 1.25" (3.2cm) I.P.S. drain. Opening(s) shall have throat liners 
constructed of high impact plastic. Unit to be insulated with foamed-in-place 
polyurethane insulation with a non-conductive top breaker strip. 
Each opening shall have an insulated, stainless steel folding lid with high 
impact plastic liner, molded rubber edge and black plastic handles.
(1) stainless steel louver shall be provided for installation in the cabinet to 
allow proper air flow to the condensing unit.
Each self-leveling mechanism shall be field adjustable by adding or remov-
ing stainless steel extension springs in the elevator housing inside the 
unit. The elevators shall be connected by removable platform carriers 
constructed of 18-gauge stainless steel.
(6) anodized aluminum divider trays will be supplied per opening. NOTE: 
See chart on back for ice cream storage capacity.
Refrigeration system shall use HFC-404A refrigerant. Refrigerant flow 
shall be controlled by an expansion valve. Cabinet shall maintain 0°F to 5°F 
(–18°C to –15°C) temperature with lids closed for storage.
Refrigeration system shall be controlled by a pressure control, located 
near the condensing unit.
Electrical connections shall be 115 volt, 60 cycle, single phase. Unit shall 
have a 9' (2.7m) long electrical cord and NEMA 5-15P installed at the 
mechanical end.
Optional accessories & modifications
  •   Lid locking device
  •   Wire baskets
  •   *Special voltages (contact factory)
       
*Inclusion of this option will alter the electrical
        specifications of the unit.