Compact Refrigerators
OPERATION
REFRIGERATED CAbINETS
After the cabinet is connected to the power source it will 
automatically begin operating. With the covers and doors 
closed, the temperature of the cabinet should reach 36°F 
to 40°F (2°C to 4°C) in about one hour. Temperature on 
salad top will maintain  33°F to 41°F (1°C to 4°C) with pans 
recessed 2.5” (6.5cm) at 86°F ambient room temperature 
for a period of four hours, meeting NSF-7 requirements. 
The temperature control on a flat top unit is located on 
the back panel inside the refrigerator and can be adjusted 
to meet the current conditions. The temperature control 
on a salad top unit is located in the rear of the unit, 14" 
to 16" above floor in access hole.
Temperature Control Instruction for Flat 
Top Units
A thermostat located in the evaporator housing on the 
interior rear of the cabinet controls the temperature in-
side the box (see Figure 4). The factory setting for the 
control is “4” and maintains about 38°F (3°C) inside the 
box. Set toward “1” for higher temperatures and toward 
“7” for lower temperatures. 
Temperature Control Instruction for 
Salad Top Units
A thermostat located in rear of cabinet controls the 
temperature inside the box (see Figure 5). The fac-
tory setting for the control is 5 and maintains about 
34°F(1°C) to 36°F (2°C) inside the box. Set toward  
1 for higher temperatures and toward 9 for lower tem-
peratures.
Figure 4. Thermostat Location - Flat Top
Figure 5. Thermostat Location - Salad Top
CAUTION
Cabinets  with  pans  should  be  operated  with  pans  in 
place. Operating the cabinet without all pans in place will 
lessen efficiency and may damage the cabinet.
Continuous opening and closing of the door will hamper 
the  cabinet’s  ability  to  maintain  optimum  refrigeration 
temperature.
Top section is not intended for overnight storage. Prod-
uct should be removed from pans. Pans can remain in 
cabinet while empty.
Defrosting
Refrigerators defrost automatically with every cycle of 
the compressor. The water generated is routed to a pan 
on the rear of the cabinet and is evaporated by the heat 
given off by the compressor.