Delfield 4448n User Manual

Page of 20
1
Compact Refrigerators
PLACE:
  • Thermostat 
• Evaporator/Condenser Fan Motor and Blade
  • Hi-limit/Thermal Protector Switch 
• Fan Delay/Defrost Termination Switch
  • Compressor Start Components and Overload Protector 
• Door Hinges, Locks, and Gaskets
LAbOR OF 2 HOURS IS ALLOWED TO REPLACE:
  • Drawer Tracks/Cartridges 
• Locate/Repair a Leak 
LAbOR OF 3 HOURS IS ALLOWED TO REPLACE:
  • Condenser or Evaporator Coil 
• Hot gas condensate evaporator 
STANDARD LAbOR GUIDELINES TO RE-
PAIR OR REPLACE PARTS ON DELFIELD 
EQUIPMENT
Advice and recommendations given by Delfield Service 
Technicians do not constitute or guarantee any special 
coverage.
A maximum of 1-hour is allowed to 
diagnose a defec-
tive component.
A maximum of 1-hour is allowed for 
retrieval of parts 
not in stock.
A maximum 
travel distance of 100 miles round trip and 
2-hours will be reimbursed.
Overtime,  installation/start-up,  normal  control  adjust-
ments, general maintenance, glass breakage, freight dam-
age, and/or correcting and end-user installation error will 
not be reimbursed under warranty unless pre-approved 
with a 
Service Work Authorization from Delfield. You 
must submit the number with the service claim.
LAbOR OF 1-HOUR IS ALLOWED TO RE-
LAbOR OF 4 HOURS IS ALLOWED TO 
REPLACE
Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery 
(includes recovery machine, pump, torch, oil, flux, minor 
fittings, solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS
R404A  A maximum of $12.00/lb. or 75¢/oz. will be re-
imbursed.