LXE 1280 Reference Guide

Page of 260
Platform Menu 
89 
E-SW-LDSPLUSRG-G 
LDS Plus Reference Guide 
Com1StopBits – COM1 Stop Bits 
Function 
The Com1StopBits parameter specifies the stop bits setting for communications port number 1 
(COM1). 
Options 
Valid options:  
1, 2 
Default setting: 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
Com1HalfDuplex – COM1 Half Duplex 
Function 
The Com1HalfDuplex parameter determines whether or not characters received on 
communications port number 1 (COM1) are echoed back to COM1. When Echo is selected, the 
characters received on COM1 are echoed back out to COM1. When No Echo is selected, the 
characters are not echoed. 
Options 
Valid options:  
Echo, No Echo 
Default setting: 
No Echo 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
Com1Xon – COM1 Software Flow Control 
Function 
The Com1Xon parameter enables or disables the use of software flow control (XON/XOFF) for 
communications port number 1 (COM1). 
Options 
Valid options:  
Disable, Enable 
Default setting: 
Disable 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3.