GE pnm1971srss Specification Guide

Page of 3
Listed by 
Underwriters 
Laboratories
Optional Accessories (Available at additional cost) 
Filler Panel Kits 
JX52
When replacing a  36" range  
hood, this kit fills in the  
additional width to provide  
a custom built-in appearance. 
For installation between   
cabinets only; not for  
end-of-cabinet installation. 
Each kit  contains two  
3"-wide filler panels.
Filter Kits
JX81J–Recirculating 
Charcoal Filter Kit
To be used when 
the Spacemaker 
microwave oven  
cannot be vented  
to the outside
.
Duct 
Equivalent Feet
A.  Rectangular-To-round 
 
 
Transition Adaptor 
5 ft.
B. Wall Cap 
40 ft
.
C. 90° Elbow 
10 ft.
D. 45° Elbow 
5 ft.
E.  90° Elbow 
25 ft
.
F.  45° Elbow 
5 ft
.
G. Roof Cap 
24 ft
.
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the 
following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard  
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round  
transition adaptor must be used. Do not use less than a 6" diameter duct. 
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to 
align exhaust with space between studs, or wall should be prepared at the time it 
is constructed by leaving enough space between the wall studs to accommodate 
exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4" 
x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS: etc., present additional resistance to 
airflow and are equivalent to a section of straight duct which is longer than their  
actual physical size. When calculating the total duct length, add the equivalent length 
of all transitions and adaptors plus the lengths of all straight duct sections. The chart 
below shows the approximate feet of equivalent length of some typical ducts. 
240278
Specification Revised 7/11
PVM1970DR 
GE Profile Spacemaker
®
 1.9 Cu. Ft. Microwave Oven