LILLIPUT 668gl-70np Specification Guide

Page of 30
I
NNO
L
U
X
       
                                                                      SPEC NO.: A070-84-TT- 12    Date : 2009/02/23             
Page : 22/27 
The copyright belongs to InnoLux. Any unauthorized use is prohibited. 
  Note 7:
 
Definition of Luminance Uniformity
   
Active area is divided into 9 measuring areas (Refer to Fig. 4-4 ).Every measuring 
point is placed at the center of each measuring area. 
                                 
max
min
B
B
(Yu)
Uniformity
 
Luminance
=
               
L-------Active area length        W----- Active area width 
 
W
W
/3
W
/3
W
/6
L/3
L/3
L/6
L
 
                                   
Fig. 4-4 Definition of measuring points 
 
B
max
: The measured maximum luminance of all measurement position. 
B
min
: The measured minimum luminance of all measurement position.