Frigidaire FPIC3095MS Installation Instruction

Page of 24
1
INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
30” Min. *
(76.2 cm)
B
C
A
I
F
D
G
H
E
All dimensions are stated in inches and (cm).
Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and 
allow space for installation of the junction box on the wall at the back of the cooktop.
IMPORTANT INSTALLATION INFORMATION
•  All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only 
electrical supply with ground.
•  Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
Cooktop Dimensions
*  30" (76.2 cm) min. for 
unprotected cabinet and
  24" (61 cm) min. for 
cabinet with protected 
bottom surface.
** DO NOT obstruct these 
areas.
Cooktop Cutout 
Dimensions
Printed in Canada
P/N 318205412 (1110) Rev. C
English – pages 1-8
Español – paginas 9-16
Français – pages 17-24
Air e
xhaust**
Fresh air intak
e**
Figure 1
4" X 8" (10.2 cm x 20.3 cm) 
opening to route armored cable 
if a panel is present
DO NOT apply any sealant 
along the perimeter. The 
cooktop must breath freely.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A 
QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
 FOR YOUR SAFETY: Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity of this or any other appliance.
United States
COOKTOP DIMENSIONS
CUTOUT DIMENSIONS
A. WIDTH
B. DEPTH
HEIGHT
E. WIDTH
F. DEPTH
G. WIDTH
H. DEPTH
I. HEIGHT
C
D
Min.
Max.
Min.
Max.
30¾ (78.1)
21½ (54.6)
3 (7.6)
4
3
/
8
 (11.1)
28
7
/
8
 (73.3)
20 (50.8)
29
5
/
8
 (75.2) 29¾ (75.6) 20
3
/
8
 (51.8) 20½ (52.1)
4½ (11.4)
36¾ (93.3)
21½ (54.6)
3 (7.6)
4
3
/
8
 (11.1)
35¼ (89.5)
20 (50.8)
35
7
/
8
 (91.1) 36 (91.4) 20
3
/
8
 (51.8) 20½ (52.1)
4½ (11.4)
Canada