INGF-070
H. IEC 60512-4-1:
Electromechanical Components for Electronic Equipment; Basic Testing
procedures and measuring methods. Test 4a: Voltage Proof.
3.
REQUIREMENTS
3.1
Design and Construction
Product shall be of design, construction and physical dimensions specified on applicable customer drawing.
3.2
Standard length
Applicable standard lengths: from 0.5meter to 20meter (both included).
For other lengths, put in contact with your sales representative.
3.3
Materials
Materials shall be in accordance to Tyco Electronics requirements about environmental-related substances as
per Tyco Electronics specification 230-702.
The material of the cable jacket is identified on the customer drawing and shall comply with the standards
mentioned in Product Specification 108-93018 Copper LAN cable.
3.4
Ratings
Operating Temperature:
-20 to 60ºC
3.5
Packaging
Each assembly shall be supplied in a clear bag.
3.6
Bending radius
The minimum bending radius is 8x outside diameter during installation and 4x the outside diameter after
installation.
3.7
Performance requirements and test procedures
Product is designed to meet electrical, mechanical and environmental performance requirements specified in
Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions.