Minuteman rpm 1609 User Guide

Page of 17
 
12 
6. Telephone Access 
 
This section will guide you through the Telephone Access to control RPM. 
1.  Dial up the RPM. 
2.  After three rings, the RPM will respond by sending out three short beeps to the 
caller.  Then the RPM waits for the user to enter the password. 
3.  The user enters an access password (default password is 123456789#). 
4.  The RPM will send out three short beeps to confirm a successful login, or one long 
beep to deny access. 
5.  Once logged in, the remote user can punch in 4-8 digits.  The first two digits 
specify which RPM, the next digit specifies which output receptacle and the next 
digit specifies which command.  The last four digits specify the amount of time: 
i. 
Command format: XXNA#: 
ii. 
XX - 00—16 is the RPM’s device number for a daisy chain, if there is no 
daisy chain, then any number is accepted. 
iii. 
N - outlet number: 1(A)—8(H), 9 controls all the outlets. 
iv. 
A - action type: 0=off, 1=on, 2=reset. 
v. 
I.E. 0111# RPM01 turn on Outlet A. 
vi. 
I.E. 0120# RPM01 turn off Outlet B. 
vii. 
I.E. 0212# RPM02 reset outlet A. 
viii. I.E. 
01113600# means turn A on after 3600 minutes. 
ix. 
I.E. 01103600# means turn A off after 3600 minutes. 
x. 
I.E. 01123600# means reset A after 3600 minutes. 
xi. 
Use a combination of 0111XXXX# or 0112XXXX# to get a different delay 
time.  XXXX max value is 9999, which is about 166 hours or 6.94 days. 
6.  Use the "*" key to cancel a command at any time. 
7.  The RPM will acknowledge the receipt of the commands by issuing 2 short beeps.  
A long beep indicates a failure or a non-recognizable command.  
8.  To change the password.  The default password is 123456789#.  The user has to 
enter the previous password in order to change their password. 
NOTE:  The Password has to have a minimum of 7 digits and can have a 
maximum of 10 digits. 
9.  The user enters 888# or whatever previous password.  Then the RPM responds 
with three short beeps acknowledging access granted.  The user then enters the 
new password as follows: 888XXXXXXXXXX#, and the RPM acknowledges with 2 
short beeps.  Then user inputs 888XXXXXXXXXX# the second time to re-confirm 
the new password.  The RPM acknowledges with 4 short beeps, indicating that the 
password has been changed. 
10.  Hang up to close any access. 
11.  Forgot telephone interface password?  Please do the following steps to restore the 
default password. 
i.  Dial up the RPM. 
ii.  After three sequence rings, the RPM will respond by sending out 3 short 
beeps to the caller and waiting for user to enter password.  Then pressing 
the button A and H simultaneously on the RPM within twenty seconds.