30" ELECTRIC DROP-IN RANGE INSTALLATION INSTRUCTIONS
Electrical Requirements
This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
fuse, having amperage as noted on the rating plate (the
rating plate is located on the oven frame).
If local codes permit, you can use a 3-wire single phase
120/208 or 120/240 Volt, 60Hz AC only electrical
system. If you connect to aluminum wiring, properly
installed connectors approved for use with aluminum
wiring must be use.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition, and local codes and ordinances.
This appliance is manufactured with a neutral (white)
power supply wire and a cabinet-connected green (or
bare copper) grounding wire.
Connect the appliance cable to the junction box through
the U.L.-listed conduit connector. Complete electrical
connection according to local codes and ordinances. (For
preferred junction box location, see Figure 1.)
Where local codes permit connecting the cabinet-
grounding conductor to the neutral (white) junction
box wire (see Figure 2)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect the appliance and the residence cable wires
as shown in figure 2.
Electrical Shock Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the junction box before
making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
• Do not use a gas supply line for grounding the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
Figure 2
 3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)