Andrew R5PNM-PS User Manual
Environmental Specifications
Operating Temperature
55 °C to +85 °C (67 °F to +185 °F)
Storage Temperature
55 °C to +85 °C (67 °F to +185 °F)
Moisture Resistance Test Method
MILSTD202F, Method 106F
Mechanical Shock Test Method
MILSTD202F, Method 213B, Test Condition C
Thermal Shock Test Method
MILSTD202F, Method 107G, Test Condition A1, Low Temperature 55 °C
Corrosion Test Method
MILSTD1344A, Method 1001.1, Test Condition A
Standard Conditions
Attenuation, Ambient Temperature
20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
R e t u r n L o s s
Frequency Band
VSWR
Return Loss (dB)
50–1000 MHz
1.04
35.00
1010–2200 MHz
1.06
31.00
2200–3300 MHz
1.08
28.00
*
Footnotes
Insertion Loss, typical
0.05√¯freq (GHz) (not applicable for elliptical waveguide)
Product Specifications
R5PNM-PS
©2010 CommScope, Inc. All rights reserved.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope.All specifications are subject to change.
See www.commscope.com/andrew for the most current information.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope.All specifications are subject to change.
See www.commscope.com/andrew for the most current information.
page 3 of 3
6/2/2010