Frigidaire fgf379wesr Installation Instruction

Page of 24
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
5
a) Install an external manual gas shut-off valve to gas
supply line in an easily-accessible location outside of
the range. Be sure you know how and where to shut-
off the gas supply to the range.
b) Install 1/2" flare union adapter to pressure regulator.
c) Attach appliance conduit to flare union on regulator.
d) Install flare union adapter to external manual shut-off
valve.
e) Attach appliance conduit to flare union on shut-off
valve.
f) Make sure service shut-off valve on pressure regulator
is in "ON" position.
g) Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.
 Do not use a flame to check for gas leaks.
Checking Manifold Gas Pressure
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing of
that system at test pressures greater than 14" of water
column pressure (approximately 1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 14" of water column
pressure (approximately 1/2" psig).
If it should be necessary to check the manifold gas pressure,
connect manometer (water gauge) or other pressure device
to the top burner right rear orifice.  Using a rubber hose
with inside diameter of approximately 1/4," hold tubing
down tight over orifice.  Turn burner valve on.
For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold pressure.
The gas supply pressure should never be over 14" water
column. When properly adjusted for Natural Gas the
manifold pressure is 4." (For LP/Propane Gas the manifold
pressure is 10.")
5. Read electrical connection details below
and connect electricity to range.
 Before servicing, disconnect electrical
supply at circuit breaker, fuse or power cord.
Electric Requirements:  An individual, properly grounded
and polarized branch circuit protected by a 15 amp. circuit
breaker or time delay fuse. See serial plate for proper
voltage.
Extension Cord Precautions:
Because of potential safety hazards under certain conditions,
we strongly recommend against the use of any extension
cord. However, if you still elect to use an extension cord, it
is absolutely necessary that it be a UL listed 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater
than the branch circuit rating. Such extension cords are
obtainable through your local service organization.
 PLEASE READ CAREFULLY!  For personal
safety, this product must be properly grounded.
Grounding Instructions
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this appliance.  The
customer should have the wall receptacle and circuit checked
by a qualified electrician to make sure the receptacle is
properly grounded and polarized.
Where a standard two-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the
customer to have it replaced with a properly grounded
three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG FROM THE POWER CORD.