Power Sub-System 
Intel
®
 Server System SC5650BCDP TPS 
 
Intel order number: E80367-002 
Revision 1.5 
 
18 
Table 15. AC Input Rating 
PARAMETER 
MIN 
Rated 
MAX 
Max Input 
Current 
Start up VAC 
Power Off 
VAC 
Voltage (110) 
90 V
rms
 100-127 
V
rms
 140 
V
rms
 10 
A
1,3
 85Vac 
+/-
4Vac 
75Vac +/-
5Vac 
Voltage (220) 
180 V
rms
 200-240 
V
rms
 264 
V
rms
 5 
A
2,3
 
 
 
Frequency 
47 Hz 
50/60Hz 
63 Hz 
 
 
 
Notes
Maximum input current at low input voltage range shall be measured at 90VAC, at max load. 
Maximum input current at high input voltage range shall be measured at 180VAC, at max load.  
This requirement is not to be used for determining agency input current markings. 
3.1.4.1 
AC Inlet Connector 
The AC input connector is an IEC 320 C-14 power inlet. This inlet is rated for 10A / 250VAC. 
3.1.4.2 
Efficiency 
The power supply has a recommended efficiency of 68% at maximum load and over the 
specified AC voltage. 
3.1.4.3 
AC Line Dropout / Holdup 
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC 
line for any length of time. During an AC dropout of one cycle or less the power supply meets 
dynamic voltage regulation requirements over the rated load. An AC line dropout of one cycle or 
less (20ms min) does not cause any tripping of control signals or protection circuits. If the AC 
dropout lasts longer than one cycle, the power will recover and meet all turn-on requirements. 
The power supply meets the AC dropout requirement over rated AC voltages, frequencies, and 
output loading conditions. Any dropout of the AC line does not cause damage to the power 
supply. 
3.1.4.3.1 
AC Line 5VSB Holdup 
The 5VSB output voltage stays in regulation under its full load (static or dynamic) during an AC 
dropout of 70ms min (=5VSB holdup time) whether the power supply is in the ON or OFF state 
(PSON asserted or de-asserted). 
3.1.4.4 
AC Line Fuse 
The power supply has a single line fuse on the Line (Hot) wire of the AC input. The line fusing is 
acceptable for all safety agency requirements. The input fuse is a slow blow type. AC inrush 
current does not cause the AC line fuse to blow under any conditions. All protection circuits in 
the power supply do not cause the AC fuse to blow unless a component in the power supply has 
failed. This includes DC output load short conditions.