Microtek 1000xl Reference Guide

Page of 6
6
The Information Window
Mouse Cursor Position
displays the x, y position of the
mouse cursor on the current
prescan    image
Pixel  Sampling  Display  Area
shows a pixelized display of the
specific x,y position of the
prescan.  The  size  of  the  sampling
area depends on the selection
made  in  the  Color  Meter  Options
(top  right)
Color  Input  Meter  Display
shows input (in density values) &
output  (in  pixel  values)  relative  to
the x,y position at the prescan
image
Color  Output  Meter  Display
shows the output values of the
pixel at x,y position (values should
differ  from  input  after  image
correction  is  complied)
Color  Output  Meter  Options
changes  color  space  mode
between  Native  &  LCH  and  size
of  the  pixel  sampling  display
area  (see  window  bottom).
Menu display
Alt+S
Scanner menu
Alt+V
View menu
Alt+P
Preferences menu
Alt+C
Correction  menu
Alt+H
Help menu
Tool selection (in Preview window)
M
Selects scan frame tool
Z
Selects zoom tool
H
Selects pane tool
D
Selects Tag window tool
Show/hide window
Shift+Ctrl+S
Brings setting window to the front
Shift+Ctrl+J
Show/hides Scan Job Queue window
Shift+Ctrl+I
Show/hides Info window
Shift+Ctrl+T
Show/hides Tag window
Shift+Ctrl+B
Show/hides white and black markers
Ctrl+O
Show/hides overview page
Ctrl+=
Zoom in
Ctrl+-
Zoom  out
File menu and Scanner menu
Ctrl+Q Exits ScanWizard Pro
Ctrl+R
Resizes Preview window to fit preview image size
Ctrl+I
Scanner Info dialog box
Preferences menu
Shift+Ctrl+C
CMS Setup dialog box
Shift+Ctrl+W
White/black point setup dialog box
Shift+Ctrl+V
Overview setup dialog box
Shift+Ctrl+P
Prescan Setup dialog box
Shift+Ctrl+M
More Preferences dialog box
AIC screen (If unspecified, the Native mode is assumed.)
Ctrl+D Dynamic range
Ctrl+W White/black points
Ctrl+V Tone curve
Ctrl+B
Brightness and contrast
Ctrl+C Color correction or color cast (LCH)
Ctrl+F
Filter
Ctrl+G Gradation (LCH only)
Ctrl+S
Saturation curve (LCH only)
Ctrl+E
Selective color (LCH)
Quick Keys