Summit External Power Supplies
The following external power supplies are available for use with Summit X159 series, X250e series, X450 
series, X450a series, and X450e series switches:
EPS-LD external power supply (
EPS-160 external power module (used with EPS-T chassis) (
)
EPS-500 external power supply (
EPS-600LS external power module (used with EPS-C chassis) (
)
EPS-150DC external power supply (used with EPS-T2 chassis) (
)
Table 35: EPS-LD External Power Supply (Model 45019)
For use with the Summit X450a-24t and X450e-24p switches
Operational voltage range
90 to 264 V
Nominal input ratings
100 to 240 V
, 50 to 60 Hz, 10 A
Input Current
6 A at 100 V
, 2.5 A at 240 V
Line frequency range
47 to 63 Hz
Maximum inrush current
30 A at 115 V
, 60 A at 230 V
Output
-50 V
, 7.5 A max, 375 Watts
12 V
, 7.5 A max, 90 Watts
Power supply cord type
AC
Power supply input socket
IEC 320 C14
Power cord input plug
IEC 320 C13
Power cord wall plug
Refer to 
.
Power supply cord gauge
18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Efficiency
>75% at 100% load
Heat dissipation, Watts, BTU/hr
123 W, 419.7 BTU/hr
Power consumption, Watts, BTU/hr
588 W, 2006.3 BTU/hr
Ambient operating temperature
0° C to 40° C (32° F to 104° F)
Maximum continuous DC output shall not exceed 465 Watts.
Table 36: EPS-160 External Power Module (Model 10907)
For use with the Summit X150-24t, X150-48t, X250e-24t, X250e-24x, X250e-48t, X450-24t, 
and X450-24x switches
Operational voltage range
90 to 264 V
Nominal input ratings
100 to 250 V, 4 to 2 A, 47 to 63 Hz
Line frequency range
47 to 63 Hz
Input current
2 A at 100 V
1 A at 240 V
Line frequency
50 to 60 Hz
Maximum inrush current 
30 A at 115 V
, 50 A at 230 V