Extreme 3802 Installation Guide

Page of 394
 
Installing and Removing Summit48si AC Power Supplies
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
127
Removing an EPS-160 from the EPS-T
To remove an EPS-160 from an EPS-T:
1
Disconnect the AC by removing the plug from the wall
2
Disconnect the AC power cord from the EPS-160.
3
Remove the redundant power cable from the EPS-160.
4
Loosen the thumbscrews on the front of the tray and slide the EPS out of the EPS-T.
Installing and Removing Summit48si AC Power Supplies
This section applies only to the Summit48si switch AC power supplies. The Summit48si comes with a 
minimum of one power supply preinstalled at the factory. If you have a Summit48si switch, follow the 
instructions in this section for removing and installing the Summit48si AC power supplies.
For information about removing and installing Summit48si DC power supplies, see “Installing the 
Summit48si Switch DC Power Supply” on page 132.
NOTE
Only trained service personnel should install or remove Summit48si power supplies.
NOTE
If you need to power down the switch, remove all the power cords from the installed power supplies.
Installing a Summit 48si AC Power Supply
To install a Summit48si AC power supply:
1
Remove the blank faceplate from the power supply bay.
2
Use the handle to slide the power supply into the bay.
3
Align and tighten the two captive retaining screws using a #2 Phillips screwdriver.
4
To turn the power supply on, connect the AC power cable to the power supply and then to the wall 
outlet.
WARNING!
Do not plug in the power cable into the power supply unless the power supply is installed in the 
switch.
5
Keep the faceplate and the power supply packaging for future use.
Removing a Summit 48si AC Power Supply
To remove a Summit48si AC power supply: