Extreme 3802 Installation Guide

Page of 394
 
160
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
Installing and Connecting Alpine 3800 Series Switch Power Supplies
NOTE
If you require DC power supplies in the Alpine 3802 switch, two power supplies must be installed. The 
Alpine 3802 switch does not support a DC power configuration using only a single power supply.
Installing an Alpine 3808 or Alpine 3804 
AC Power Supply
This section describes how to install an AC power supply for either the Alpine 3808 or the Alpine 3804 
switch. The Alpine 3802 switch power supply is preinstalled at the factory. 
Complete the following tasks before installing the power supplies:
You need the following tools and equipment to install the Alpine 3808 and the Alpine 3804 AC power 
supplies:
ESD-preventive wrist strap (provided)
# 2 Phillips screwdriver
To install an Alpine 3808 or Alpine 3804 AC power supply:
1
Attach the ESD strap to your wrist and connect the metal end to the ground receptacle on the top 
right corner of the switch front panel.
2
If a blank faceplate is covering the power supply bay, remove it and save it for future use.
3
Prepare the power supply for installation:
Use the text on the front of the power supply to ensure that it is oriented correctly for either the 
Alpine 3808 or Alpine 3804.
Move the safety latch to the “remove” position.
Open the ejector/injector lever, as shown in Figure 87 and Figure 88.
Table 30: Supported power supplies for the Alpine 3800 series switch
Switch Model
AC power supply
DC power supply
Hot-swappable
Alpine 3808
1
Up to two AC power supplies 
can be installed.
Up to two DC power supplies 
can be installed.
Yes
Alpine 3804
Up to two AC power supplies 
can be installed.
Up to two DC power supplies 
can be installed.
Yes
Alpine 3802
Up to two AC power supplies 
can be installed.
2
Two DC power supplies must 
be installed.