Configuring I/O Modules
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
199
connection to the Mogul-100. For more information about Mogul-100 configuration, see the Mogul-100 
Quick Guide
.
Configuring the FM-8Vi.  
The VDSL connection from the FM-8Vi to the Mogul-100 is automatically 
established by the hardware on the two devices. There are no commands to configure this VDSL 
connection.
However, the VDSL ports on the FM-8Vi connect to the Mogul-100 in such a way that the Ethernet port 
on the Mogul-100 behaves as though it is located on the Alpine switch. When you configure a port on 
the FM-8Vi, you are configuring the Ethernet port on the Mogul-100. For example, when you add port 2 
on the FM-8Vi to a VLAN, the Ethernet port on the Mogul-100 connected to port 2 of the FM-8Vi now 
belongs to that VLAN.
The ports on the Mogul-100 that are controlled by the FM-8Vi accept configurations using the same 
commands and procedures as the ports on the FM-32Ti and FM-24Fi modules, except that the ports can 
only be configured for 10 Mbps.
The slot configuration command now includes a keyword to specify the FM-8Vi. To configure the slot 
for the FM-8Vi, use the following command:
config slot <slot> module fm8v
The following example configures slot 2 for the FM-8Vi module:
config slot 2 module fm8v
Displaying VDSL Statistics.  
For the FM-8Vi module, the show port command has been enhanced to 
show VDSL statistics. To display VDSL statistics, use the following command:
show port <portlist> vdsl stats
The following command displays the VDSL statistics for ports 2:1 through 2:4:
show port 2:1-2:4 vdsl stats