Extreme 3802 Hardware Manual
Configuring I/O Modules
Extreme Networks Consolidated Hardware Guide
173
Table 50 lists the pin numbers on the connector, the color code for the wires, and the associated port
number for the wire pair.
number for the wire pair.
LEDs
The FM-8Vi module has the following LEDs:
•
Module status
•
Port status
For information about the LEDs and their activity on the FM-8Vi module, see “I/O Module LEDs” on
page 176.
page 176.
Software Requirements
The FM-8Vi module requires that the SMMi has ExtremeWare software version 6.1.5 or later and
BootROM 6.5 or later. For more information about software requirements and module configuration, see
the ExtremeWare Release Notes Software Version 6.1.5w2.01 Rev1. The FM-8Vi module also requires a
connection to the Mogul-100. For more information about Mogul-100 configuration, see the Mogul-100
Quick Guide.
BootROM 6.5 or later. For more information about software requirements and module configuration, see
the ExtremeWare Release Notes Software Version 6.1.5w2.01 Rev1. The FM-8Vi module also requires a
connection to the Mogul-100. For more information about Mogul-100 configuration, see the Mogul-100
Quick Guide.
Configuring the FM-8Vi.
The VDSL connection from the FM-8Vi to the Mogul-100 is automatically
established by the hardware on the two devices. There are no commands to configure this VDSL
connection.
connection.
However, the VDSL ports on the FM-8Vi connect to the Mogul-100 in such a way that the Ethernet port
on the Mogul-100 behaves as though it is located on the Alpine switch. When you configure a port on
the FM-8Vi, you are configuring the Ethernet port on the Mogul-100. For example, when you add port 2
on the FM-8Vi to a VLAN, the Ethernet port on the Mogul-100 connected to port 2 of the FM-8Vi now
belongs to that VLAN.
on the Mogul-100 behaves as though it is located on the Alpine switch. When you configure a port on
the FM-8Vi, you are configuring the Ethernet port on the Mogul-100. For example, when you add port 2
on the FM-8Vi to a VLAN, the Ethernet port on the Mogul-100 connected to port 2 of the FM-8Vi now
belongs to that VLAN.
The ports on the Mogul-100 that are controlled by the FM-8Vi accept configurations using the same
commands and procedures as the ports on the FM-32Ti and FM-24Fi modules, except that the ports can
only be configured for 10 Mbps.
commands and procedures as the ports on the FM-32Ti and FM-24Fi modules, except that the ports can
only be configured for 10 Mbps.
The slot configuration command now includes a keyword to specify the FM-8Vi. To configure the slot
for the FM-8Vi, use the following command:
for the FM-8Vi, use the following command:
config slot <slot> module fm8v
Table 50: RJ-21 connector and wire pairs
VDSL
Port
Port
Ring Side
Pin Number/Wire Color
Pin Number/Wire Color
Tip Side
Pin number/Wire Color
Pin number/Wire Color
1
1 blue white
26 white blue
2
2 orange white
27 white orange
3
3 green white
28 white green
4
4 brown white
29 white brown
5
5 slate white
30 white slate
6
6 blue red
31 red blue
7
7 orange red
32 red orange
8
8 green red
33 red green