Extreme 3802 Hardware Manual

Page of 336
 
Installing I/O Modules
Extreme Networks Consolidated Hardware Guide
177
1 The Diag LED is on the WM-4T1i module only.
2 The slowly blinking LEDs cycle once per second. 
3 The rapidly blinking LEDs cycle twice a second.
Installing I/O Modules
You can insert I/O modules at any time, without causing disruption of network services. 
You need the following tools and equipment to install an I/O module:
ESD-preventive wrist strap
Port 
(all except 
FM-24MFi and 
FM-24SFi)
Green
Flashing green
Amber
Off
Link up
Disabled
Packet activity
Link down
Port 
(FM-24MFi 
and FM-24SFi 
only)
Green
Flashing green
Off
Link up
Packet activity
Link down
Table 52: Alpine Access I/O module LEDs (silver stripe)
LED
Color
Indicates
Status
Off
Amber 
Green 
No power
Module seated in chassis
Module powered up
Diag
1
Green blinking
Off
Power-on Self Test (POST) is running
Normal operation
WAN port 
(1-4)T1/E1
(1)T3
Amber
Amber rapidly blinking
1
Amber slowly blinking
2
Green
Alternating green and 
amber
Green rapidly blinking
2
Green slowly blinking
3
Near-end fault has been detected (for example, no 
cable)
Far-end fault has been detected
Physical link is present, but no higher-layer link 
(port is misconfigured or disabled)
Physical link is present, higher-layer link is 
established, but no traffic is present
Physical link is present, higher-layer link is 
established, and traffic is present
Loopback testing mode is in progress
Port is active, but disabled
10/100 port
(5,6)T1/E1
(2,3)T3
Off
Green
Alternating green and 
amber
No link is present
Link is present
Traffic is present
Table 51: Alpine I/O module LEDs (green stripe) (continued)
LED
Color
Indicates