Extreme 3802 Installation Guide

Page of 390
 
Installing and Removing the Internal 600 Watt AC Power Supply (15412)
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
121
Removing an EPS-LD unit
To remove an EPS-LD unit:
1
Disconnect the AC power by removing the plug from the wall.
2
Disconnect the AC power cord from the EPS-LD unit.
3
Disconnect the cable between the Extreme switch and the EPS-LD unit.
4
Remove the screws from the EPS-LD mounting brackets.
5
Slide the EPS-LD unit out of the rack.
Installing and Removing the Internal 600 Watt AC Power 
Supply (15412)
The Summit 300-48 600 Watt AC power supply (15412) is designed to be used in the Summit 300-48 
switch. While powering the Summit 300-48, the 600 W power supply is capable of providing 450 W of 
power to Power over Ethernet (PoE) devices connected to the 48 primary PoE ports. Refer to the 
Summit 300-48 Release Notes to determine the total available power at each port. You can obtain copies 
of these documents at the Extreme Networks web site at:
http://www.extremenetworks.com/services/
The switch has two power supply bays, so a redundant power supply can be installed. When used in 
redundant mode, the power supplies are hot-swappable. You can add a second power supply without 
powering off the switch. If redundant power supplies are installed, you can remove one of them 
without powering off the switch.
This section includes the following procedures:
Installing a cable retaining bracket
Removing cable retaining bracket
The Summit 300-48 comes with a minimum of one power supply pre-installed at the factory. Switches 
with one power supply have a metal cover plate in place of the second supply. If you install a second 
power supply, be sure to retain the cover plate in case you later decide to use only one supply.
Table 23: LED status for EPS-LD Power LED
Power LED
Indicates
Green, solid
Off
The external power supply is operating normally.
The external power supply is not connected.