Switch Installation
This chapter describes the following topics:
CAUTION
Use of controls or adjustments of performance or procedures other than those specified herein can 
result in hazardous radiation exposure.
Determining the Switch Location
The Summit24e3 switch is suited for use in the office, where it can be free-standing or mounted in a 
standard 19-inch equipment rack. Alternately, the device can be rack-mounted in a wiring closet or 
equipment room. Two mounting brackets are supplied with the switch.
When deciding where to install the switch, ensure that:
The switch is accessible and cables can be connected easily.
Water or moisture cannot enter the case of the unit.
Air-flow around the unit and through the vents in the side of the case is not restricted. You should 
provide a minimum of 25 mm (1 inch) clearance.
No objects are placed on top of the unit.
Units are not stacked more than four high if the switch is free-standing.