Intermec 5055 Reference Guide

Page of 216
5055 Programmer’s Software Kit Reference Manual
7-14
Command Processing
Purpose:
Command processing allows you to disable or enable reader commands.
You may want to disable reader commands to prevent a user from accidentally entering
a command or to use data that would otherwise be treated as a command. Any bar code
label that contains the 2- to 4-character commands for Command Processing is treated
as a reader command unless the command is disabled.
Syntax:
DCdata
Acceptable values for data are:
0
Disable all reader commands
1
Enable all reader commands
2
Disable override
3
Enable override
command0
Disable reader command
command1
Enable reader command
The override option is a temporary setting that allows you to enable all the reader
commands for as long as you need them. When you want to return to the previous
configuration, you disable the override.
Note:
 The Enable Override option is the only bar code label you can scan to enable
reader commands if you have disabled all reader commands (DC0).
Default:
Enable all reader commands
Scan:
To enable all the reader commands or override the current settings, scan one of these
bar codes:
Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC2*
*$+DC3*
*$+DC2*
*$+DC3*