Intermec 6400 Reference Guide

Page of 234
Supporting DOS Applications
SECTION 2
PEN*KEY6400 Programmer’s Reference Guide 2-7
Table 2-1 (continued)
641223 Options
Switches
Description
–U
Unload TSR, if safe to do so.
–W
Enable the wedge mode of operation. Scanner data is sent to the
keyboard buffer, using the method selected by the –P switch.
The absence of –W requires an application to request scanner data
through the API scanning method.
Integrated Long Range Laser Engines
For integrated long range laser engines, the aiming beam needs to be setup. The
switch to set the long range aiming beam for the scanner is:
641223 –An
where “n” is the number of 1/2 second intervals.
6400 Laser Engine Decode Capability
There are some differences in the capabilities of the internal laser engine used in
the 6400 and the non-decoded laser technology used in the RF terminals. The
1122 and the 1223 scanners are supported as described in the following table.
Table 2-2
6400 Laser Engine Decode Capability
Symbology
Supported for 1122
Supported for 1223
ABC Codabar
No
No
Code 93
No
Yes
Code 11
No
No
Computer Identics 2 of 5
No
No
Straight 2 of 5
No
Yes
UPC–E
Number system 1 shelf la-
bels are not supported
Yes
MSI Plessey
Yes, except alpha characters
are not supported
Yes
Interleaved 2 of 5
Decodes 1 of 2 fixed lengths,
no minimum or maximum
range.
Yes