SECTION 3
TouchBase Driver
6500/6550 Computer Technical Reference
3-17
Calibration
Calibration enables the software to accurately align touch
with the mouse cursor. This procedure must usually be
done only once, as part of the initial software installation,
and only needs to be repeated if the alignment of the touch-
screen with the visual image changes, for example when
you change or adjust the monitor.
1. Click the Calibrate button to start the calibration
program.
2. Touch the screen where the two
8
s appear, the posi-
tion of which the driver stores in the Windows 95 Reg-
istry.
If calibration was successful, a confirmation window
appears. Click OK to continue:
You can call the program to perform calibration immediate-
ly from entry as follows. You may wish to build this call
into your application:
T5ctrl /c:CALIBRATE