Intermec cv60 Installation Instruction

Page of 36
1
Introduction
Chapter
3
CV60 DC-DC Converter Installation Guide
A pair of green light-emitting diodes (LED), located near the
output connectors on the power supply, will be lit whenever
voltage is supplied to the output power cables.
One LED indicates main power is OK (3 pin connector). The sec-
ondary power LED will indicate Heater Power (2-pin connector) is
OK.
Note: If the secondary LED is not lit when using
both main and secondary power outputs, input pow-
er to the DC-DC converter is probably less than
9-10 volts.
Green LEDs
(power output indicators)
Output Connector
(secondary power)
P/N 851-070-003 6-60V, 14A
Input Connector
Output Connector
(main power)
Input Power Cable
Note: The input power cable may be shortened as need-
ed. It should NOT be extended on 12V or lower systems.
On higher voltage systems, extensions should be kept to a
minimum and should be of equivalent or higher gauge
wire. Keep the cable as short as possible. Extra cable picks
up noise, adds power loss and is prone to snagging on
equipment.
The input power cable is approximately 9 feet long. One end has
a 4-pin connector, the other has a 2-pin connector. Cut off the
2-pin connector and terminate it for connection to the vehicle power
source.
Inline Fuse
A snap-twist inline fuse holder is furnished as part of this kit. It
must be connected as close as possible (electrically and physically)
to the vehicle power source. It provides catastrophic failure,