Intermec 5020 User Guide

Page of 116
Chapter 4 — CK61, CV30, and CV60 Computers (Windows CE)
52
Data Collection Browser User’s Guide
8
Tap Yes to save the changes.
9
To close Intermec Settings, tap the X button in the upper right corner of 
the screen.
10
Perform the steps in “Starting the dcBrowser Client for the First Time” 
in the next section.
Starting the dcBrowser Client for the First Time
1
Select Start > Programs > dcBrowser. A splash screen appears showing 
the dcBrowser title and version number.
2
To set the IP address and port number of the dcBrowser gateway, tap 
(Press Here for Setup).
3
Press Enter to save your configuration.
Connecting to the dcBrowser Gateway
After you have loaded and configured the dcBrowser client on your 
Intermec computer, change the following parameters in the .ini file for the 
dcBrowser gateway.
For the software-only dcBrowser gateway, the .ini file is DCB.INI. For the 
dcBrowser on an Intermec Application Server, the .ini file is WBS.INI.
To change the INI parameters
1
Open the .ini file in a text editor, such as Notepad.
2
Change the parameters to the required values.
3
Save the changes to the .ini file.
4
Exit the text editor.
You are now ready to start the dcBrowser client and connect to the gateway.
Note: If the dcBrowser client has not been configured with a valid IP 
address and port number, the IP configuration screen automatically 
appears.
INI File Parameters
Parameter
Change Value to
INPUT_HIGHLIGHT
INVERSE
ANCHOR_HIGHLIGHT
UNDERLINE
SUBMIT_HIGHLIGHT
UNDERLINE
TAB_TO_SUBMIT
TRUE
TAB_TO_ANCHOR
TRUE