Intermec ck1 User Guide

Page of 172
Chapter 2 — Configuring the CK1 
CK1 Handheld Computer User’s Manual 
39 
Telepen 
Telepen provides the full ASCII character set. For convenience 
of handling, characters with ASCII values of less than 32 are 
reproduced in the font at the character positions chr$(192) to 
chr$(223). The space character, ASCII 32, is reproduced at 
ASCII 159 and 160. 
Some Telepen symbols require the first character (after start) be 
an ASCII Shift In character and the last character (before stop) 
be a Shift Out character. The ASCII ESC character is required 
on some Telepen Numeric systems as the first character after the 
start character. If you are using a Telepen system, your system 
manual describes the scheme you require. 
All Telepen symbols must begin with a start character and end 
with a stop character. The start character is §(Chr$(167)) and 
the stop character 
¬
 (Chr$(172)). 
You can configure the following options for Telepen: 
•  Enable 
•  Standard character set 
EAN 128 
While other symbologies encode data with no respect for what 
the data represents, EAN 128 encodes data and encodes what 
that data represents. EAN 128 has a list of application 
identifiers. Each identifier tells the system what kind of data will 
follow and in what format. 
You can configure the following options for EAN 128: 
•  Enable 
•  Enable ID 
•  Function (1 to 255) which is the ASCII value of the character 
returned when there is a Function code in the bar code.