Chapter 6—Configuration Command Reference 
240 
Trakker Antares 2400 Family System Manual 
Scan a value for data from the “Full ASCII Bar Code Chart” on page 
284. The server certificate common name can be from 1 to 32 
characters. 
Scan this bar code: 
  Exit Accumulate Mode 
 
*-/* 
 *-/* 
Start of Message (SOM) 
 
Terminals:  All Trakker Antares terminals. 
 
Description:  SOM is the first character in a message sent to or received from the host 
computer through one of the terminal’s serial ports. You can configure 
LRC for the Configurable communications protocol. For more 
information, see the networking chapter in your user’s manual.  
You can set SOM to use characters from the extended ASCII character set 
using the TRAKKER Antares 2400 Menu System. This procedure is 
similar to the one for setting the preamble and postamble. For help, see 
“Entering ASCII Control Characters” in the configuration chapter in your 
user’s manual. 
SOM cannot equal the same value that is set for EOM. You cannot set 
SOM to any of these values:  
• AFF (ACK) 
• REQ (ENQ) 
• DLE 
• SEL 
• NEG (NAK) 
• XOFF 
• Poll 
• XON 
• RES (EOT) 
 
 
Note: Before you can enable SOM, you must configure the EOM 
command. 
 
Syntax: YYn.data 
where n is: 
COM1 serial port 
COM2 serial port (246X and 248X terminals only) 
COM3 serial port (242X terminals only) 
COM4 serial port (242X, 2455, and 248X terminals only) 
An acceptable value for data is any ASCII character. 
 
Default:  \x02 (hexadecimal value for STX)