Trakker Antares 2400 Family System Manual 
327 
Limitations of ROM-DOS 
The Trakker Antares terminal supports a limited set of DOS. Here are the 
limitations:  
•  Applications cannot interact directly with hardware nor memory 
locations such as timer ticks. 
•  Ctrl-Alt-Del is not supported. Use the Reset Firmware command or 
boot the terminal. For help, see “Booting the Terminal” or “Resetting 
the Terminal” in the troubleshooting chapter in your user’s manual. 
•  DOS batch file commands are all supported except LOADHIGH (no 
high memory is available). 
•  Some DOS processing commands are not supported because 
DOS=HIGH, DOS=UMB, DEVICEHIGH=n, and DOS switches are 
not supported. 
•  RAMDRIVE.SYS is not compatible with the Trakker Antares terminal. 
You can use VDISK.SYS as a replacement for this DOS driver. For 
help, see “Configuring a DOS RAM Drive” on page 325. 
The following table lists the BIOS interfaces that are supported and those 
that are not supported by ROM-DOS on the Trakker Antares terminal. 
ROM-DOS BIOS Interfaces 
BIOS Interface 
Supported? 
Notes 
INT 10H – Display Functions 
 
 
 
INT 10H function 0EH 
Yes 
 
 
INT 10H functions 0H, 
2H, 3H, 6H, 7H, 8H, 9H, 
13H 
Limited 
These functions are limited by 
the lack of PC-compatible 
hardware on the Trakker 
Antares terminal. 
INT 11H 
Yes 
 
INT 12H 
Yes 
 
INT 13 
No 
The Trakker Antares terminal 
contains flash memory rather 
than a disk drive. 
INT 14H – Compatibility 
Functions 
 
 
  INT 14H functions 01H–
03H 
Yes  
  INT 14H functions 0H 
Limited 
This function is limited by the 
existing Trakker Antares system 
interface. 
INT 15H function 4F 
Yes