 Chapter 4—Running Diagnostics 
Trakker Antares 2400 Family System Manual 
75 
2455, 2475, and 248X Terminals 
 
Where Available:  Hardware Diagnostics menu, Battery/PIC Status, and then choose either 
Main Battery/PIC or Backup Battery/PIC. 
Sample Screen: 
24XXS050.eps
BATTERY/PIC
MONITOR
Main
Board
Temp:
-30C
(00)
IO
Board
Temp:
-30C
(00)
EEPROM
Checksum:
OK
I2C
Mstr
Bus:
OK
PIC
Rev.:
0
[Esc]
Exit
 
24XXS051.eps
BATTERY/PIC
MONITOR
Backup
Battery
Good
Backup
Battery
Volts
10.80V
(BC)
Temp:
25C
(A4)
Backup
Charging:
NO
PIC
Rev.:
8
[Esc]
Exit
 
Main Battery/PIC Screen 
  Backup Battery/PIC Screen 
 
Definition:  The Main Battery/PIC screen does not provide information about the 
main battery because 2455, 2475, and 248X terminals do not have a main 
battery. Instead, this screen reports the temperature of the main board and 
the I/O board, as well as the status of the EEPROM checksum and the 
master bus. 
The Backup Battery/PIC screen displays the status of the backup battery. 
Battery Status Descriptions 
Status 
Description 
Good 
The backup battery is operating correctly. No action is required. 
Low 
The backup battery needs to be charged. For help, see “Charging the Backup 
Battery” in Chapter 1 of the 2455, 2475, or 248X user’s manual. 
Bad 
The backup battery may be disconnected or not operating correctly. If you 
have a 2455, you can check if the backup battery is connected or replace it. 
For help, follow the instructions in “Replacing the Backup Battery” in 
Chapter 4 of the 2455 user’s manual. If you have a 2475 or 248X, contact 
your local Intermec service representative. 
 
 
 
Note: The NiCad backup battery in the 2475 and 248X is not user-
serviceable. You must return the Trakker Antares 2475 or 248X terminal 
to Intermec to replace the backup battery.