Intermec 2430 User Guide

Page of 374
nugget
 
39 AGaramond
 Chapter 4—Running Diagnostics 
Trakker Antares 2400 Family System Manual 
79 
Sample Screen: 
24XXS063.eps
ERROR
LOGGER
Current
Time:231912
Time
Err#
Address
024401
0003
90000548
024359
0002
90000548
024358
0001
90000548
[Enter]
Next
screen
[Esc]
Exit
 
 
Definition:  The Error Logger screen shows the last 30 errors in three columns:  
•  The first column displays the time in HHMMSS format. 
•  The second column displays the error number. To learn which error 
message is associated with the error number, see “Error Numbers and 
Messages” on page 87. 
•  The third column displays the internal firmware address, which helps 
identify why the error occurred. 
Press ; to see the next screen of errors. 
Font Test 
 
Purpose:  You can use this diagnostic to identify which double-byte font, if any, you 
have loaded on your terminal.  
 
Where Available: Software 
Diagnostics menu 
Sample Screen: 
FONT
TEST
No
Double
Byte
Font
Loaded
[Esc]
Exit
24XXS064.eps
FONT
TEST
DB
Font
13
[Esc]
Exit
 
 
Definition:  If you ordered the optional 4MB flash memory for your terminal, you can 
use the Trakker Antares Font Loader to download a double-byte font set 
to the terminal. See your local Intermec sales representative for 
information about ordering double-byte fonts. 
Use this table to match the font number with the double-byte font that is 
loaded on your terminal.