Intermec 2430 User Guide
nugget
39 AGaramond
Chapter 4—Running Diagnostics
Trakker Antares 2400 Family System Manual
79
Sample Screen:
24XXS063.eps
ERROR
LOGGER
Current
Time:231912
Time
Err#
Address
024401
0003
90000548
024359
0002
90000548
024358
0001
90000548
[Enter]
Next
screen
[Esc]
Exit
Definition: The Error Logger screen shows the last 30 errors in three columns:
• The first column displays the time in HHMMSS format.
• The second column displays the error number. To learn which error
message is associated with the error number, see “Error Numbers and
Messages” on page 87.
Messages” on page 87.
• The third column displays the internal firmware address, which helps
identify why the error occurred.
Press ; to see the next screen of errors.
Font Test
Purpose: You can use this diagnostic to identify which double-byte font, if any, you
have loaded on your terminal.
Where Available: Software
Diagnostics menu
Sample Screen:
FONT
TEST
No
Double
Byte
Font
Loaded
[Esc]
Exit
24XXS064.eps
FONT
TEST
DB
Font
13
[Esc]
Exit
Definition: If you ordered the optional 4MB flash memory for your terminal, you can
use the Trakker Antares Font Loader to download a double-byte font set
to the terminal. See your local Intermec sales representative for
information about ordering double-byte fonts.
to the terminal. See your local Intermec sales representative for
information about ordering double-byte fonts.
Use this table to match the font number with the double-byte font that is
loaded on your terminal.
loaded on your terminal.