2. KEY (Keypad Test)
Select option 2.KEY from the Diagnostic menu for the Keypad Test:
KEYPAD TEST
Wait key . . .J
Press any key and the ASCII symbol should appear. Press " to exit, and
the following prompt appears. Press [1] to return to the Diagnostic menu,
or press [0] to continue with the keypad test.
KEYPAD TEST
Exit_? J
1=YES/0=NO
3. 232 (RS-232 Loopback Test)
Select option 3.232 from the Diagnostic menu for the RS-232 Test testing
status screen. A signal is sent from the TXD pin through a loopback con-
nector to the RXD pin. The received signal is verified to match the trans-
mitted signal. A full ASCII table code (0-255) test pattern should be in
each test cycle. Communication parameters should equal default values,
except the baud rate.
RS232 TEST
Baud= 9600 PASS
Baud=19200 PASS
Baud=38400 PASS
Baud=57600 PASS